+ Partsfps Kitchen Equipment: October 2021

Friday, October 29, 2021

True Freezer Troubleshooting

The True freezer is one of those appliances that tends to go unappreciated until it's not freezing as it should. However, many things can go wrong with your True manufacturing freezer. As there are just as many simple fixes, you can try these fixes to get the unit back to keep in perfect condition. Have a look at these True freezer troubleshooting tips.



True Freezer Troubleshooting Guide

Find out the solutions for True Freezer not freezing, operates continuously, compressor problems, etc.

Freezer Running but Not Cold

We will see the basic operation of the cooling system in your True freezer before start the troubleshooting process.

The compressor releases a refrigerant to the condenser. The condenser coils transform the refrigerant from vapor to liquid while releasing heat which you feel blowing near the unit while it is in a cooling cycle. The cooler refrigerant flows into the evaporator through an expansion valve. From the evaporator, it absorbs heat from the freezer and cools the contents. After that, the refrigerant moves into a warm vapor, then returns to the compressor and repeats the cycle.

However, a disruption in the cooling cycle stops your freezer from cooling. So, you need to verify many factors that contribute to this issue. Before going into depth fixes, you have to fix some minor issues.

Thermostat

The temperature setting might be raised accidentally. If this is the case, simply adjust it.

Check for the defective thermostat as it does not send power to the refrigerant system.

To see if the thermostat is working properly, change the thermostat setting from lowest to the highest. If you notice a clicking sound, consider that there may not be a problem with the thermostat. Also, check the continuity of a thermostat using a multimeter. If it has no continuity, you need to replace the thermostat.

Defrost Timer

You should remove the freezer's plug while testing the defrost timer. Manually advance the defrost cycle by using a screwdriver. You need to turn the advancement screw clockwise until you hear the click sound. When you notice a click, this advances the cycle to the next mode. Wait for 30 minutes or one hour and inspect if it has resumed cooling. If the defrost timer is not advance, you have to replace it.

Evaporator Coils

Generally, the defrost heater melts any frost that accumulates on the evaporator coils. If this frost is faulty, frost will continue to accumulate on the evaporation coils. You can test the heater with a multimeter for continuity. If it doesn't have continuity, you will have to replace the heater. In addition, dirty condenser coils may cause to not transfer heat or cold efficiently.

Compressor

You can find the compressor at the bottom of the freezer. It emits a steady noise or humming sound that indicates that it is running. Clicking sound indicates that the compressor is overloaded or overrunning. If there is no clicking sound but your freezer is not cooling, then there may be an issue with the compressor or its components. So, you have to test each component and replace if it is defective. Also, check the start relay. If it smells burnt, it needs to be replaced.

Relay is Defective or Burned Out

You may have an improper size relay. Check and replace it if necessary.

The relay should be mounted at the correct angle.

Line voltage could be too high or too low.

Relay is being influenced by loose vibrating mounting. You have to remount it rigidly.

Incorrect run capacitor might be the reason behind this problem. So, you have to place the correct capacitor.

Suction Line Frosted or Sweating

Expansion valve passing excess refrigerant or is oversized - You need to readjust the valve or replace it with a smaller one.

Expansion valve stuck open - Clean the valve. Replace if necessary.

Check whether the evaporator fan is running or not.

True Freezer Stuck in Defrost Mode

If your freezer is stuck in the defrost cycle, you need to inspect the timer. A timer is the only component that controls defrost system. You can simply advance it out of defrosting.

Unplug your freezer from the outlet. Next, locate a small hole under the control panel and you will find a knob in the center of hole. Manually turn the knob in a clockwise direction. When you notice a loud click sound, it will be out of defrost and back in the normal cooling mode. Plug the unit back in and it should start operating.

Final Words

Hope this True  Freezer troubleshooting guide helps you more to get back your unit running effectively. However, the way you treat your freezer, it will treat you in return. So, you should follow the regular maintenance tips to eliminate basic and common True freezer problems.

Thursday, October 28, 2021

Honeywell Water Heater Troubleshooting

Do you have problems with your Honeywell water heater? Quickly diagnose and repair your water heater with our comprehensive troubleshooting guide. The chances are a bad thermocouple has shut off the gas to the pilot light or an issue with the pilot light. This article will show you how to fix Honeywell electric and gas heater.  







Honeywell Water Heater Troubleshooting

You can observe a green LED indicator on the water heater gas control when your Honeywell water heater not working. The error codes on the LED status will indicate the issue by reporting a number of flashes.

l O flashes - Control off or Pilot out

l 1 flash - Normal operation

l 2 flashes - Thermopile voltage is low

l 4 flashes - Temperature exceeded

l 5 flashes - Sensor failure

l 7 flashes - Gas control valve failure

l 8 flashes - Power off failure

The thermopile generates electricity in the Honeywell water heater that is needed to power the gas control valve. It will take up to 90 seconds to get hot enough to power the gas control valve once the pilot is lit. When it happens, the status light will blink once every 3 seconds which indicates normal operation. If the light blinks more than once every three seconds, you need to refer to the status light code list or label on the gas control valve.

Try lighting the pilot by following the lighting instructions given in the manual or on the heater and visually confirm the pilot can be lit. Next, set the gas control knob to "Pilot". Hold the control knob in while clicking the igniter button and looking through the inside water heater to the left. In order to see the pilot, you may have to dim the room lights.

If there is air in the gas line, it may take up to 90 seconds before the pilot lights and the status light begins to blink. Even after 90 seconds also, if the status light won't start blink, you have to release the control knob and turn off the gas valve.

You should wait ten minutes before attempting to relight the pilot. On newly installed water heaters, it may take 2 to 3 lighting attempts before the pilot lights and status light starts blinking.

Two flashes and three-second pause - Weak pilot signal is detected.

The system will reset when the pilot flame is sufficient. Thermopile failure, unstable pilot, blocked/ restricted pilot tube, or opened resettable thermal switch might be caused this problem. You can check the troubleshooting tips in the service manual.

Three flashes and three-second pause - Insufficient water heating.

The temperature sensor could be out of calibration. Check and recalibrate it.

Four flashes and three-second pause - Excessive tank temperature.

Check for faulty gas control and verify if the temperature sensor is out of calibration.

Final Words

We hope our guide on Honeywell water heater status light codes and Honeywell water heater troubleshooting was helpful and it was able to get back your unit running. When you need to go through Honeywell water heater thermostat replacement or controller replacement, it's better to call a professional. Still, if your Honeywell water heater not working, refer to the manual and fix the issue.

How Does A BASO Switch Work?

Do you want to know how does a BASO pilot safety switch work? You have reached the right place to get the details on BASO switch. Here, we have provided the information regarding the BASO pilot switch working process, installation, importance, etc. So, have a look at this blog post to get the details on Baso pilot safety switch.



How Does a BASO Pilot Safety Switch Work?

BASO pilot switches are used on all gas-fired and standing pilot equipment that requires the main burner to shut off when the pilot is extinguished. Typical applications include domestic central heating and commercial space heating appliances as well as industrial processing equipment.

These pilot switches monitor the pilot flame through the use of a thermocouple. In 100% shutoff model applications, if the pilot flame is extinguished, then the switch will be interrupted gas flow to the pilot burner as well as the main burner and caused for shutting down the appliance.

In non- 100% shutoff model applications, the switch will interrupt gas flow to the main burner only when the pilot flame is extinguished. Pilot gas will continue to flow until the pilot gas is manually shut off. 

L61 BASO Pilot Switch

The L61 is an automatic resetting device that opens the main gas valve electrical circuit if the pilot flame is extinguished. Lighting or relighting the pilot burner causes the device to close the electrical circuit of the main gas valve and allowing the appliance's main burner to operate.

This switch receives its energy from a heated thermocouple. Because BASO L61 has features like automatic resetting and minor pilot flame fluctuations which may cause the device to drop out and will not shut down the unit permanently. Moreover, it will automatically close and restore service upon resumption of a normal pilot flame. L61 models are available with Single Pole Double Throw switching actions when an additional switching function like a need of signal light.


BASO Safety Shutoff Device Installation

Before starting the installation process, you should turn off the power to the appliance.

Shut off the gas at the main manual shutoff valve adjacent to the appliance.

Remove the device cover by loosening the screws at the side.

Now, mount the switch in any convenient position using the mounting holes provided.

Push the circuit wires through the conduit opening on the bottom of the device. Strip the ends of the wires just enough to put the bare wire under the terminated screws and attach them to the two-wire terminals.

Replace the cover. Do not loosen the grass hex nut.

Attach the thermocouple securely to the pilot burner. And, screw the terminal end to the BASO power unit terminal on the pilot switch. Ensure that this connection is secure. Tighten the thermocouple lead nut finger tight that is finger tight plus a maximum of 1/8 turn. You should not overtighten it.

Check the Adjustments after Completion of BASO Switch Installation

Make sure all components are functioning properly by performing the following tests.

Test all joints and connections for leaks with a soap solution.

Set the thermostat to the lowest setting.

Close the main manual shutoff valve and pilot valve and wait at least 5 minutes for unburned gas to escape from the appliance.

Reopen the pilot valve and ignite pilot gas and wait for 30 to 45 seconds.

Push down the red indicator and aluminum reset button to its full limit of travel and release. If the red indicator remains depressed, the unit is operative. If the red button doesn't stay depressed, wait for another 30 seconds and try again. If the second attempt also not successful, check that the thermocouple output meets the desired value.

Open the manual main shutoff valve after the red indicator button remains in the depressed position. The main burner will ignite from the pilot burner when the thermostat calls for heat.

Disconnect the thermocouple from the device. The main shutoff valve should close immediately. If it is not closing, you have to check for wiring errors. Once, you have decided there are no wiring errors, reconnect the thermocouple to the pilot switch.

Re-light the pilot and observe at least 3 complete operating cycles to make sure that all components are functioning correctly.

Reset the thermostat to a normal temperature setting before leaving the installation.

Conclusion

Hope the information updated above on the BASO pilot switch useful for you. If you know the basic working process, installation, and testing, then you can easily fix the problems yourself when it has trouble.

Tuesday, October 26, 2021

York Air Handler Troubleshooting

When there is a problem with any Heating, Ventilation, and Air Conditioning system, we feel very uncomfortable. The York air handler has designed with many electrical and mechanical components so that can get problems from time to time. Some of the common York air handler problems may help you identify the issue and possibly fix it. You can avoid the most common problems with regular maintenance of the air handler unit.



York Air Handler Troubleshooting
When your air handler doesn't work properly, there are many areas to check for problems in and around the unit. The following initial checks are necessary before resolving any issues.

Compare phase of power supply and voltage with rating plate numbers.
Check the wiring diagram connections between the control panel and remote panel.
Verify the gas type and supply pressure with the official rating information.
See for proper blower rotation on the unit and any exhaust blowers.

Clogged or dirty evaporator coil
If the evaporator is dirty, it causes to freeze and reduce the cooling capacity of the unit. So, you need to try turning off the thermostat for 1 to 3 hours and examine if it will defrost. Verify whether there are indications of water leakage below the indoor unit. If you observe any leaks and unable to defrost the coil, you have to contact an authorized specialist.

Blower Motor is Not Functioning
Sometimes excessive dust can build up and cause the motor to burn out. When you didn't replace the air filter, this type of problem may happen. Also, check for the blower motor failure. If the blower motor is failed, you have to replace it.

York Air Handler Maintenance
A clean filter saves money.  Ensure the top efficiency of the air handler by cleaning the filter regularly. When the unit circuit and filters the air in your home, dust and dirt particles collect on the filter located in your indoor unit. Excessive buildup forces the unit to run longer to maintain your set temperature.

Clean or replace the filter
You should clean or replace the air filter at least once a month or twice when your system is running more time. If it is a semi-permanent filter, you can take out the filter and vacuum it. If you have a disposable filter, it should be replaced every month. When replacing the filters, use the same size and type that was originally supplied. You can buy these filters at PartsAPS. Along with this, you have to do the following:

Ensure fan blades are free of dust buildup.
Moving parts should be free of cracks and excessive wear.
Test if the fan RPM meets your design specifications.
Clean dampers of dirt accumulations.
Tighten bearing collar screws on fan shaft.
Confirm damper actuators and linkages are operational and aligned.
Check all coils, leaks, valves, refrigerant lines, fittings, etc.
Examine the rust in condensation pans and drains.
Check all belts for signs of wear and cracks.
Verify all belts for signs of wear and cracks.
Drain and remove moisture from all cooling coils.
Vacuum the whole air handler properly.
Align rigid couplings properly.
Listen for excessive noise or vibrations.
How to Change Air Handler Air Filter?
First, locate your filter. It may be located behind the bottom panel of your indoor unit. Some models have two filters.

Remove the old filter. While inserting the new one it should be clean. By following the directions pointed in the manual, you have to insert a new one.

Now, replace it with a new filter. Make sure you use the same size and type of filter.

When you are going out for a few days or when outdoor temperatures are decreased, don't run the air handler unnecessarily.

Conclusion:

Your York air handler is responsible for evenly distributing cool and warm air throughout your home. So, you should perform maintenance tasks regularly to increase the life span of your system. But, with so many parts, obstructions can happen in your unit that causes for not to run as it should. However, use our York air handler troubleshooting guide to fix the problems. If you want to replace any York parts, buy from us at a low cost.

Blodgett Oven Installation

Blodgett ovens represent the latest advanced technology in energy efficiency, reliability, and ease of operation. In these ovens, heat is normally lost and is recirculated within the cooking chamber before being vented from the oven that resulting in substantial reductions in energy consumption and enhanced oven performance. However, in this blog, we have updated the process for Blodgett oven installation. Take a look at this complete post.



Blodgett Oven Installation Procedure

Cooking in a Blodgett convection oven is different from cooking in a conventional deck or range oven since heated air is constantly recirculated over the product by a fan in an enclosed chamber. The moving air continually strips away the layer of cool air surrounding the product and quickly allowing the heat to penetrate. The result is a high-quality product, cooking at a lower temperature in a shorter amount of time. Now, check out how to install a Blodgett convection oven.

Oven Location

If you placed the oven at the proper level. Then, it will give the long-term operator convenience and satisfactory performance.

You need to maintain the below clearances between the oven and combustible or non-combustible construction.

Oven body right side - 1 inch.

Body left side - 1 inch.

Oven body back - 7.5 inches

Body bottom - 4.5 inches

Make sure there will be an adequate air supply to the oven to provide a sufficient flow of combustion and ventilation air.

The area where you have to place the oven that should be free of drafts.

Try to keep the area free as well as clear of all combustibles such as cardboard, paper, solvents, and flammable liquids.

Don't place the unit on a curb base or seal to a wall. Because this will restrict the flow of air and prevent ventilation. An excessive ambient temperature on the right side of the oven caused to tripping of the blower motor's thermal overload device. So, you should correct this condition to avoid permanent damage to the unit.

Leg Attachment

Need to push your oven onto a lift with the bottom of the unit down.

Align the threaded stud in each leg with the nut located inside each bottom corner of the oven's frame. Now, turn the legs clockwise and tighten to the nearest full turn.

You have to align the two-leg plate holes in each leg with those in the oven bottom. Fix the leg with two 1/2" bolts.

Now, level the Blodgett oven by screwing the adjustable leg feet in or out as necessary.


Blodgett Oven Assembly

Secure the short legs to the bottom sections.

Place the upper section in position on top of the lower oven.

You have to place the clips over the edge of your oven frames.

Tighten the clips by bolting together with 3/8" bolts and nuts provided.

Now, attach the flue connector.

Gas Host Restraint

If the Blodgett oven is mounted on casters, you should use a commercial flexible connector with a min of 1.9 cm inside diameter along with a quick-connect device.

You will get this restraint along with the oven that is used to limit the oven's movement. So, no strain is placed upon the flexible connector. Installation of the restraint with a fully stretched connector is easy and quick connect.

The restraint should be attached without damaging the building. Don't use the electrical conduit or gas piping for the attachment of the restraint's permanent end.

Mount the bracket to the leg bolt just below the gas inlet. And, attach the clip-on restraining cable to the mounting bracket.

Final Words

That’s all about Blodgett oven installation. However, the installation should be done by a professional or expert to avoid dangerous problems. If you need further more assistance, you can refer to your Blodgett oven manual. Installation instructions may vary from model to model.

 

Monday, October 25, 2021

ASCO Red Hat Solenoid Valve - How to Select, Installation & Maintenance

 ASCO Red Hat Solenoid Valves are used for the control of fluids. These valves are available in various models, each designed to meet specific requirements. Are you new to use ASCO Red Hat Solenoid Valve? We are here to help you by providing useful information regarding ASCO Red Hat Valve. If you need to know how to select ASCO Red Hat and Red Hat II Solenoid Valves, installation and troubleshooting, read this entire post, it may help you.







Two Way Valves

Two-way valves have one inlet and outlet pipe connection. These will help you for normally open and closed operations. Normally opened valves are open when the coil is de-energized and close when the coil is energized. Normally closed valves are closed when the valve is de-energized and open when the proper voltage is applied to the coil.

Three Way Valves

Three way valves are designed with three pipe connections and two orifices which are alternatively opened or closed. These ASCO valves are available for normally closed, open or with universal construction that is used as normally closed or normally open. Three way ASCO Red Hat Solenoid valves are mainly used as pilots for larger control valves to actuate single-acting cylinders or to divert the flow of fluids.

Four Way Valves

These valves have four pipe connections. One for exhaust, one for pressure and two for operating double-acting cylinders. Four way valves are used to pilot larger control valves.


Manual Reset Valves

Manual reset valves will be closed or opened manually and then revert to their original position when they are energized or de-energized. These are used for preventing the inadvertent startup of critical systems.

After determining the basic ASCO solenoid valve type, while selecting, you should consider pipe size including flow rate, orifice size, pressure rating, ambient & fluid temperatures, medium to be controlled, type of solenoid enclosure, voltage, cycling rate and required life rating. Each factor's importance needed to be determined by the application itself.

ASCO Red Hat Valve Installation and Maintenance

To increase the valve life, you should install and maintain it properly. However, you need to read and follow the instructions given on the red hat and red hat II valve for each model.

Installation

You must check the nameplate data for voltage, pressure, etc. to ensure compatibility with your system conditions. Moreover, you have to know that the solenoid enclosure type with your operating conditions.

Some red hat valves will operate in any mounting position, while others have to be mounted in a certain way to operate correctly. However, it's better to install these valves with the solenoid in a vertical upright position. If you install the valve in a vertical upright position, there will be less chance of foreign matter accumulation in the core tube area. You need to install the filter or strainer as close as possible to the red hat valve inlet.

The wiring should have complied with the local codes and the Canadian Electrical Code. Make sure you don't pull out from the coil. If you are not using a flexible conduit for transition into the valve, the supply conduit should support properly to reduce stress on the solenoid assembly.

Final Words

Hope you got an idea about ASCO Red Hat Solenoid Valve and your job might be done easier to select the appropriate ASCO Red Hat Valve and installing. For further more information on the ASCO Red Hat II Solenoid Valve, you can refer to the valve manual. Moreover, PartsAPS offers ASCO solenoid valves so you can buy here if you need them. 

Friday, October 22, 2021

Star Deep Fryer Troubleshooting

Star Manufacturing deep fryers are important in most commercial kitchens. And, it's common to experience malfunction once in a while. That's why it is important to know some of the most common Star deep fryer problems and their fixes. It's easy to fix the basic issues that come with your fryer. Let's start reading a few problems and tips to solve the problems of Star Mfg deep fryer.


Star Deep Fryer Troubleshooting Guide

Find the simple solutions to fix the basic Star fryer problems

Deep Fryer Pilot Won’t Light/ Pilot Light is Out

If the fryer's deep pilot light is out, you can consider that your unit is completely out of condition. The oil does not heat up to its right temperature without a pilot light. There are many reasons behind the deep fryer pilot light out. But, mainly due to the main gas supply valve issue, this problem will occur.

Check the supply line for any blockages, this is the best choice to confirm that problem is with the gas supply valve. While inspecting, if you observe that the supply valve is open and clog-free, then you have to replace the thermopile. The thermopile works as a main heating element in the fryer that converts thermal heat into electric energy. Therefore, signaling the pilot light to ignite the flame. It is fairly simple to replace the thermopile. If you are unable to replace it, contact a professional.

Thermostat Failure

If you are seeing temperature fluctuations when using the Star Mfg deep fryer, it might because of a defective thermostat. When the temperature is off, it's likely that the fryer will continue to burn or undercook your fried and correct recipes until the problem is fixed.

If you notice any problems with the heating capabilities of oil, you should place a probe-style thermometer inside the oil for testing its average temperature. When you are testing, the temperature must be consistent. If the oil temperature is inconsistent while testing, you will need to re-calibrate/ rewire or replace the internal thermostat. Also, check the wires behind the fryer thermostat are disconnected. If so, connect them properly.

Hi-Limit Switch is Not Working

Sometimes, you may get problems with hi-limit thermostats. Hi-Limit thermostats are placed inside the fry tank near the burners. Like an internal thermostat, the hi-limit switch caused to not heat the frying oil to its arranged temperature. If this switch is a reason for your deep fryer's inconsistent oil temperature, replace it to resolve the issue. If you don't know how to replace the hi-limit switch, you can call a service technician.

Poor Oil Circulation

If the fryer oil filter fails, the flow of oil will become weak and makes it impossible to complete the deep fry food successfully. You will hear and see the oil circulation sound when your Star deep fryer is turned on if it's filtration pump is operating properly. If your oil flow becomes weak, you can simply change the oil filter. Sometimes, this will work effectively. But, in some situations, the O-rings could not fully tight & secure. Damaged O-rings often interfere with a stable air pressure balance. So, you should fix them carefully even it is easier. Otherwise, need a professional technician to get complete functionality.

Conclusion

That’s all about a few common problems of your Star manufacturing deep fryer issues and their solutions. Hope, this Star commercial deep fryer troubleshooting tips helped you while fixing basic problems. However, it’s necessary to follow regular maintenance to avoid these types of common problems. If you need further more assistance regarding Star deep fryer troubleshooting, you can refer to the manual. For replacement or repair needs, buy Star Mfg fryer parts at our store.

 

HOW TO CLEAN SMELLY REFRIGERATOR

Overtime, it is common for your refrigerator to build up an unpleasant aroma. A nasty smell in the fridge is not great. So, you just how to get rid of refrigerator smells. It's important to remove the source before it spreads throughout the unit. However, removing the smell from your refrigerator is pretty easy and preventing future smells is easier. Continue to read this post to know how to clean smelly refrigerator.




How to Clean Smelly Refrigerator?

You can remove the smell from your refrigerator using odor removers. Check out natural methods that you can make simply for avoiding nasty smells in your fridge.

Before starting to clean a smelly fridge, you should remove all items from the refrigerator. Also, discard the items that are expired or spoiled. Wipe down any containers with a cloth that have exposed to food residue or sticky. You need to remove the mechanical components of the unit such as shelves, racks, drawers, etc. Soak these removed components in soapy hot water as you clean the rest of the interior.

Baking soda and vinegar are natural odor absorbers. So, clean the unit with these natural products. For the clean-up process, it's better to use a microfiber cloth or a new sponge that won't be broken and easily fall apart. Use a toothbrush or a thing rag to clean small spaces where food particles might be fallen. To clean better and help to prevent the odor causing bacteria spread, you must use quality tools.

Once your fridge is empty, from starting wipe it down with a cloth. Make sure, wipe underneath the drawers and scrub the ceiling, doors and sides. Remember that, you must clean the exterior surfaces as well, as they can transfer odors to the inside.

After that, rinse the cloth with warm water and rinse away the vinegar and baking soda residue where you scrubbed. Remove all cleaning solution trances by continuous rinsing. Now, you can replace the food. But, the temperature inside the refrigerator is below 5 degrees centigrade. If your unit has a fast cool function feature, use it to speed up the cooling process. 

How to Get Rid of Smell in Fridge with Baking Soda?

Baking soda has no smell on its own so that it won't create any side problems to other food items in your refrigerator. It is a great thing while absorbing and neutralizing other bad smell aromas. Open up the baking soda box and place it on the back of the top shelf for about 3 days.

If the fridge smells bad, pour a full box of baking soda across a baking sheet and leave it in the unit overnight. In the morning, you have to discard it.

How to Clean a Smelly Fridge using Lemon?

As lemon provides a refreshing scent, many people like it for removing odors in the fridge. Squeeze half of the lemon juice onto a cloth and wipe down the plastic components of your unit. Leave the remaining lemon on a plate and place it in the fridge for one or two days.

Preventing Fridge Bad Smells and Odors in the Future?

Look at your refrigerator and remove the expired food to prevent odors. If you follow this, foul smells won't build up in the first place. Remember that it is much easier to prevent bad odors than eliminate them from your fridge.

Store the fresh items such as vegetables, fruits, meat, etc. in a location where you will be able to see them daily. Fresh foods can easily go bad so you should check them daily. If you notice any items starting damage, dispose of them immediately. This is the best preventative method for nasty smells.

Keep the temperature range of the fridge in between 35 to 38 degrees F. If the temperature in your refrigerator increases above 40 degrees F, then bacteria will grow and food will begin to smell.

Keep leftovers in a sealed airtight container to last longer and prevent foul smells.

Wrap Up

A clean refrigerator not only makes you feel better about food storing, but also makes your food tasty for a longer period. We hope this article about how to clean a smelly refrigerator helped you to make your task easier. You should clean inside surfaces and dry them thoroughly with a soft cloth.

Wednesday, October 20, 2021

Vulcan Gas Convection Oven Troubleshooting

Convection ovens are hotter and cook faster than conventional ovens. With the many advanced features in the Vulcan gas convection ovens, we are getting yummier baked goods, meats and more. However, over a long period of usage, it gets problems. When something goes wrong with your Vulcan gas convection oven, you need to know how to fix it. So, we are here to help you by giving some Vulcan gas convection oven troubleshooting tips.




Blower Motor Does Not Run in "Cool Down or ON" Position

Look at the following things to resolve this problem.

Variations in the line voltage.

Malfunction with the power switch.

Switch, S3 malfunction.

Malfunctioning with the interconnecting wiring.

Check for the inoperative motor.

Blower Motor Run in "Cool Down", but not in "ON" Position

See if there is a malfunction with the door switch.

Verify the interconnecting wiring. If it is wrong, you need to adjust the connections.

Power switch contacts might be inoperative.

Gas Doesn't Ignite/ No Spark/ No Ignition Light ON

Check for the shorted electrode on ignitor or flame sense.

Heat relay, R3 might have malfunctioned.

A high voltage ignitor cable is opened.

An inoperative transformer might be caused the issue.

The high limit thermostat could be opened.

Check for the malfunction of interconnecting wiring.

Sometimes, it might be caused by an ignition module.

Sparks but Gas Doesn’t Ignite

The gas solenoid valve may be in OFF or inoperative mode.

Check if the manual gas valve is closed.

There might be insufficient gas pressure and gas supply OFF.

A faulty ignition module could be caused your oven gas does not to ignite.

Also, inspect for interconnecting wiring malfunction.

Gas ignites but will Not Maintain Flame

If your convection oven is not maintaining flame, there might be an issue with the ignitor. Hence, check for the following:

Malfunction with the ignitor lead connections.

Check whether the ignitor ground is operative or not.

There could be insufficient gas pressure.

Ignitor or flame sense malfunction.

Snorkel vent plugged, obstructed or missing.

Incorrect polarity from the transformer to the ignition module.

Vulcan Gas Convection Oven Doesn’t Heat

When your oven is not producing heat or not cooking your food perfectly, you have to check the malfunction of the high limit switch, probe, and control. You will need to replace these components if necessary. It is used for computer control models.

Vulcan Full Size Gas Convection Oven Error Codes

The error code will display on the oven's display. It will alternate between the code and the unit's cavity temperature. If you didn't find the error on display, check for environmental noise, electrical noise or vibration.

Er01 - ROM Checksum Error

It will be caused by an internal ROM malfunction. You can fix this error with the cycle power.

Er02 - RAM Checksum Error

Because of internal RAM malfunction, Er02 will occur. With cycle power, it is able to fix the problem.

Er03 - Ambient Sensor Error

If the ambient temperature is below 32 degrees Fahrenheit, you can get this error code. So, you need to verify the ambient temperature at the control.

Er04 - Configuration Error

It will occur because of microprocessor malfunction. Cycle power might be the solution.

Er05 - EEprom  Error

It indicates that the power loss while storing data.

Er06 - Zone 1 A/D Underflow Error

When an incorrect sensor type is used or measuring temperature is outside the specified range, the 06 code occurs.

Final Words

Hopefully, this Vulcan gas convection oven troubleshooting guide will help you to fix the problems yourself and save money. However, we may not be covered solutions for some other Vulcan convection oven problems. If you didn’t get the fix, refer to your oven’s model Vulcan manual.




Tuesday, October 19, 2021

Scotsman Pebble Ice Maker Cleaning

Keeping the Scotsman pebble ice maker clean ensures you have plenty of fresh-tasting ice. You should descale and sanitize your pebble ice maker regularly. But, do you know the Scotsman pebble ice maker cleaning process? If not, read this post. Here, we are going to share an easy method for your Scotsman pebble ice machine cleaning.


Scotsman Pebble Ice Machine Cleaning

Generally, twice per year, you can remove scale on unit and perform sanitizing. But, in some areas water contains significant quantities of minerals so the water system in the ice maker becoming coated with these minerals. Hence, it requires frequent maintenance than every 6 months. Check out the simple procedure for scale removal and sanitizing.

1. Press and release the ON/ OFF button. The green light will blink for a minute and the unit will shut off.

2. You have to remove all ice from the bin.

3. Remove the scoop and fold metal bar flush to the bin wall.

4. Remove the ice maker's back panel by loosening thumbscrews. Lowering the panel and remove it from the front side.

5. Now, find the reservoir, push tab, lift and remove the cover.

6. Push ON/ OFF lever up to shut off the water.

7. You need to pull the drain plug to the drain system and return the plug.

8. Cut 1/2 inch off the end of the squirt nozzle with a pair of scissors and add approximately half of the bottle or 8 oz of premixed Scotsman clear 1 scale remover into the reservoir until half full.

9. Press and hold both ON/ OFF and Clean Reset buttons for 5 seconds. Then, the yellow light will start blinking. The Auger motor only will operate for ten minutes and then the compressor will turn on.

10. Allow the compressor to run and continue to add solutions maintaining the level at 1/2 full while the unit makes ice. You can hear normal noises such as squealing. The compressor will shut off after 40 minutes approximately..... know more click here

When is the Time to Clean Scotsman Pebble Ice Maker?

One can clean the ice maker when:

Ice is getting too cloudy,

When ice cubes are getting smaller than normal,

When ice cubes are melting quickly,

If you feel the taste of ice as a drink,

When the exterior and interior of the machine are dirty.

When ice cubes are getting dirty.

Conclusion

Hope you knew how to clean a Scotsman pebble ice maker. Clean the machine frequently as per the manufacturer’s recommendations. With cleaning, not only you will always get nicely shaped, but you will also extend the unit’s life along the way. If you have any doubts about the Scotsman pebble ice maker model, you can refer to the manual.

Monday, October 18, 2021

York Heat Pump Troubleshooting

As York heat pump provides both cooling and heating, it may seem like there are many possible causes when something goes wrong. A heat pump unit doesn't operate somewhat differently than an air conditioner. So, here are ways to find out what may have gone wrong with your York heat pump and potentially resolve the issues rather than calling a repair person. In some cases, you can prevent and solve the issues on your own when you are aware of the York heat pump troubleshooting.











Thermostat problems
First of all, you should check that your thermostat has set at the right modes. If every setting is correct, the problem could be a miscalibration. Due to this miscalibration, your thermostat read the temperatures incorrectly, Although, there may be an electrical problem that stops the thermostat from communicating with the heat pump. In these cases, you need to contact a professional for servicing.

Power Issues
Sometimes, a tripped circuit breaker is caused for this problem. Make sure all the breakers are in the proper positions. If the circuit breaker is tripped, you have to reset it to avoid electrical issues. Also, check for other electrical issues. If you have a minimum knowledge of electrical components repairing, then you can fix the problem immediately. If not, contact an electrician or a professional.

Defective starter capacitor
Once listen to your heat pump unit. If you hear a faint clicking noise, then consider that your system is supposed to be turning on and the problem is likely with the starter capacitor. A starter capacitor is used to transmit the electrical charge that turns on the motors. So, you have to check for the starter capacitor is broken. If so, you need to replace it.

Broken reversing valve
As the name indicates, the reverse valve allows the unit to work as both an air conditioner as well as a heater by reversing the refrigerant direction. If you start the heat pump when you need cool air, but it produces heat, then it is likely caused by this valve. If it is damaged.

Heat Pump is Not Cooling
Thermostat problem - You have to check to see that the thermostat is set to cool mode. If the thermostat is set to cool correctly, then there may be a problem with the thermostat not reading the temperature correctly or an electrical problem stops the element from communicating the system. If you are unable to identify the cause or fix it, call a professional.

Broken reversing valve - If your unit is running, but hot is coming from vents, there could be a problem with your reversing valve. Reversing valve reverses the refrigerant and allows it to act as both a heater and an air conditioner. If this valve is defective, it needs to be replaced. You can take the help of a technician for replacing this valve.

Components are dirty - If the air coming out of your vents is lukewarm, that is a sign that your components are dirty. Go outside and clean off the heat pump so it's free of any debris and check the air filter to see if it needs to be changed.

Refrigerant charge is low - Again you need to inspect the refrigerant levels. If they are too low or if there is any leak, your system will unable to cool your house. Fix leaks if there are any existed and increase the levels.

Conclusion
If your York heat pump is experiencing repeated problems and not performing to your needs. Then, you have to think about investing in a new system or find a new service provider that can better meet your needs. You can buy new York heat pump parts from PartsAPS. For further details, refer to the York heat pump manual.

Sunday, October 17, 2021

Blodgett Oven Installation

Blodgett ovens represent the latest advanced technology in energy efficiency, reliability, and ease of operation. In these ovens, heat is normally lost and is recirculated within the cooking chamber before being vented from the oven that resulting in substantial reductions in energy consumption and enhanced oven performance. However, in this blog, we have updated the process for Blodgett oven installation. Take a look at this complete post.







Blodgett Oven Installation Procedure

Cooking in a Blodgett convection oven is different from cooking in a conventional deck or range oven since heated air is constantly recirculated over the product by a fan in an enclosed chamber. The moving air continually strips away the layer of cool air surrounding the product and quickly allowing the heat to penetrate. The result is a high-quality product, cooking at a lower temperature in a shorter amount of time. Now, check out how to install a Blodgett convection oven. Before unpacking the oven, you should verify the damages in the package as well as unit.

Oven Location

If you placed the oven at the proper level. Then, it will give the long-term operator convenience and satisfactory performance. You need to maintain the below clearances between the oven and combustible or non-combustible construction.

Oven body right side - 1 inch.

Body left side - 1 inch.

Oven body back - 7.5 inches

Body bottom - 4.5 inches

Make sure there will be an adequate air supply to the oven to provide a sufficient flow of combustion and ventilation air.

The area where you have to place the oven that should be free of drafts.

Try to keep the area free as well as clear of all combustibles such as cardboard, paper, solvents, and flammable liquids.

Don't place the unit on a curb base or seal to a wall. Because this will restrict the flow of air and prevent ventilation. An excessive ambient temperature on the right side of the oven caused to tripping of the blower motor's thermal overload device. So, you should correct this condition to avoid permanent damage to the unit. Make sure, the location provides sufficient clearance for the air opening into the combustion chamber.

Oven Leveling

After completion of the assembling process, your oven should be leveled and moved to the operating location. It can be leveled by adjusting casters or feet located on the bottom of each leg.

On gas oven models, the installation of a proper ventilation system can't be over-emphasized. This system will remove unwanted vapors and products of combustion from the operating area.

Gas Host Restraint

If the Blodgett oven is mounted on casters, you should use a commercial flexible connector with a min of 1.9 cm inside diameter along with a quick-connect device.

You will get this restraint along with the oven that is used to limit the oven's movement. So, no strain is placed upon the flexible connector. Installation of the restraint with a fully stretched connector is easy and quick connect.

The restraint should be attached without damaging the building. Don't use the electrical conduit or gas piping for the attachment of the restraint's permanent end.

Mount the bracket to the leg bolt just below the gas inlet. And, attach the clip-on restraining cable to the mounting bracket.

Final Words

That’s all about Blodgett oven installation. However, the installation should be done by a professional or expert to avoid dangerous problems. If you need further more assistance, you can refer to your Blodgett oven manual. Installation instructions may vary from model to model.

Friday, October 15, 2021

Honeywell Water Heater Troubleshooting

 Honeywell Water Heater Pilot Light Won’t Light

Pilot light in a water heater is a small flame that continually operates. When you turn on your hot water tap, the hot water flows out to the fixture. When you need hot water, the gas valve will open up and the pilot light will ignite the fuel.

Whether the pilot light is lit or not, a small amount of gas will flow continually from the gas supply line. The pilot light would combust the gas and turning it into heat and flue gases. Without the pilot light, gas could continue to fill up your water heater closet or garage.



The status light may not blink due to many reasons including:

The pilot is not lit

Air in the gas line

The thermopile is not hot enough

Tripped thermal switch

Gas control valve wiring is bad or the connectors are loose

Thermopile is bad

The thermopile generates electricity in the Honeywell water heater that is needed to power the gas control valve. It will take up to 90 seconds to get hot enough to power the gas control valve once the pilot is lit. When it happens, the status light will blink once every 3 seconds which indicates normal operation. If the light blinks more than once every three seconds, you need to refer to the status light code list or label on the gas control valve.

Try lighting the pilot by following the lighting instructions given in the manual or on the heater and visually confirm the pilot can be lit. Next, set the gas control knob to "Pilot". Hold the control knob in while clicking the igniter button and looking through the inside water heater to the left. In order to see the pilot, you may have to dim the room lights.

If there is air in the gas line, it may take up to 90 seconds before the pilot lights and the status light begins to blink. Even after 90 seconds also, if the status light won't start blink, you have to release the control knob and turn off the gas valve.

You should wait ten minutes before attempting to relight the pilot. On newly installed water heaters, it may take 2 to 3 lighting attempts before the pilot lights and status light starts blinking.


Gas Control Valve Troubleshooting

Check out the Honeywell water heater status light codes, descriptions and possible remedies.

No LED Status - Electrical power not present

It may because of the control switch in the "OFF" position. Otherwise, the supply voltage will be interrupted. So, you have to slide the switch to "ON" position.

One flash and three-second pause - If the setpoint is in "Pilot" position then the pilot flame is detected. Turn set point knob to the desired setting. There might be gas control is powered and waiting for the setpoint knob to turn to a water temperature setting.

It's a normal operation. You have to adjust the thermostat to the desired temperature setting.

LED on continuously - Setpoint knob has been turned to the "OFF" position. Wait until the LED status goes out before attempting to relight.

When the pilot is lit, LED will go out and the control will function normally.

Two flashes and three-second pause - Weak pilot signal is detected.

The system will reset when the pilot flame is sufficient. Thermopile failure, unstable pilot, blocked/ restricted pilot tube, or opened resettable thermal switch might be caused this problem. You can check the troubleshooting tips in the service manual.

Three flashes and three-second pause - Insufficient water heating.

The temperature sensor could be out of calibration. Check and recalibrate it.

Four flashes and three-second pause - Excessive tank temperature.

Check for faulty gas control and verify if the temperature sensor is out of calibration.

Final Words

We hope our guide on Honeywell water heater status light codes and Honeywell water heater troubleshooting was helpful and it was able to get back your unit running. When you need to go through Honeywell water heater thermostat replacement or controller replacement, it's better to call a professional. Still, if your Honeywell water heater not working, refer to the manual and fix the issue.


Wednesday, October 13, 2021

How to Clean Pitco Fryer

 How to Clean Pitco  Fryer?

Perform the initial & daily cleaning of the fryer as described below. Also, you can check out the instructions for how to boil out a Pitco fryer.




Initial Cleaning

Generally, while shipping many parts of the Pitco fryer are coated with oil for protection. So, you should clean it before starting the cooking. If you clean it, oil coating will be removed and removes any foreign particles that are accumulated during shipment or storage. You can follow the cleaning process as below given.

 Fill the tank with water and add a mild detergent or one packet of Pitco fryer cleaner.

 Turn on your fryer and set the thermostat temperature to 200 degrees Fahrenheit. Leave the unit for 15 minutes to heat. Make sure the water level is not below the oil level mark on the back of the fry tank.

 With a fryer cleaning brush, you have to scrub the interior for removing the protective coating.

 After completion of fryer cleaning, turn off the main burners and turn the gas valve knob to the "Pilot" position.

 Now, drain the water from tank to a container that is suitable for hot water.

 When the fryer's tank is cooled, rinse it thoroughly with cool water. You need to continue to rinse it until the cleaner is removed completely from the tank.

 Wipeout all water with a clean dry cloth. You should wipe out the water thoroughly as any residual water causes hot oil to splatter out of the unit.

Note: Mild steel tanks must be wiped down or coated with oil to keep the tank free from rusting.

 Now, the tank is clean and you are ready to fill and operate your fryer.


Daily Cleaning

If you have done this procedure daily, your Pitco fryer will run effectively and give peak performance for years to come.

 Wipe down the exterior fryer: With a clean soft or microfiber cloth, you need to wipe up shortening that spills onto the exterior surfaces of the Pitco fryer. Better to do this when the oil is warm.

 To clean unit surfaces, use a mix of warm water and mild detergent. Make sure not to get water in the shortening. Rinse the fryer completely and dry thoroughly before use.

 Use a non-abrasive scouring powder or pad to clean stains if you find stains from grease or other food remnants.


Weekly Cleaning - How to Boil Out a Pitco Fryer?

The Pitco fryer has to be cleaned once a week. This is the right time if you want to replace the filter paper. The cleaning includes complete draining of the fryer and boils out.

You will need a large container to hold the volume of the tank. This container should also be able to withstand boiling water temperatures. When the oil is replaced by water or heating portion cleaning is completed, you have to shut off the fryer completely. This will prevent the heating system from coming on during the oil draining and water filling procedure.

You have to drain the oil from the fryer and discard it. You can also reuse it. Remove tube rack or mesh tube screens and remove any debris from the bottom of the fry tank. Clean them. Once the cleaning is completed, return mesh screens and tube racks to the fry tank. Close the drain valve and fill the tank with a mixture of non-caustic detergent and water. You can use cleaner for best results.

Restart the fryer. When the temperature of unit gets 100 degrees centigrade, it will go to "Boil" mode and bring the water to a slow boil. Once the water is at a slow boil, turn off the unit.

Soak the fryer for 20 minutes to soften shortening deposits and carbon. By using a fryer brush, remove any residue from heating tubes, tank, and sidewalls. You need to perform standard daily cleaning after scrubbing the tank.

Remove the filter from the unit. Next, slide a container to catch the water under the fryer so that the pipe which is normally aimed into the filter pan is aimed into the container and open the drain valve.

Drain the hot water to the taken container and rinse the fry tank with clean warm water.

Wipe the fry tank dry with a clean cloth. After that, close the drain valve and remove the container. Now, refill the tank.

Tuesday, October 12, 2021

Trane Heat Pump Reviews

Trane Heat Pump Reviews

Trane has been manufacturing heating, ventilation, and cooling equipment since 1881. Trane has a reputation of being a quality manufacturer with its products being able to last for years. With that said, Trane heat pumps reviews are mostly favorable.









What is Trane Heat Pump?

A Trane heat pump is a device that absorbs heat from the air and transfers it to the inside. It works by pulling in cool outdoor air and heating it before transferring it to your home's heating system. Because the heated air is dry, you can use a dehumidifier that produces less humidity.

How Does Trane Heat Pumps Compare to Other Brands?

Trane is dedicated to provide high-quality, innovative, and reliable systems to facilitate its customers. Here, we have given some key points that make Trane heat pumps stand out from the competition.

Unique designs

Trane heat pumps are unique because they build and test their parts. The members of the Trane company use innovative ideas to craft their heating systems way beyond regular standards. That's why Trane's name got popular among others. However, Trane products will be provided with innovative, unique and high-quality.

Extreme Testing

Trane follows a rigorous testing process to ensure that each of its products is strong, efficient and durable. For testing, the products will put through up to 4 months of extreme cold and blistering heat. While other products are put through over 2500 continuous hours for rigorous testing. Moreover, they encase Trane units in solid ice to ensure they keep running. This testing procedure helps the Trane HVAC units to provide the best experience.

Carefully Selected Specialists

Trane has a special position to be known as a Trane comfort specialist. They won't give everyone the honor of being their dealer. For installation, best service, employee training, and customer satisfaction, Trane has highly qualified professionals. This makes Trane company dedicated to provide the best services to their customers.

Energy Efficiency and Cost-Effectiveness

Trane heat pumps are extremely cost-efficient. They will save money from the start of your usage. These products have a higher HSPF rating, which means they create the most heat by utilizing the least amount of energy. With the higher Heating Seasonal Performance Factor (HSPF) rating. You can save more money. Trane is effective at that point.

Warranty

Each Trane unit comes with a simple "Base Limited Warranty". This warranty involves the parts that are damaged due to manufacturing faults. Normally, this base limited warranty range from 1 to 20 years depends on the product you bought.

If you register your product within 60 days of the installation date, you can get a "Registered Limited Warranty" without any additional costs. This warranty can range from 5 years to a lifetime. Moreover, they will offer an "Optional Extended Warranty that covers the cost of Trane heat pump parts and labor as well. All these warranty options, surely take Trane way ahead of their competition.

Trane Heat Pumps Models and Specifications

Here, SEER indicates Seasonal Energy Efficiency Rating, refers to cooling and HSPF indicates Heating Seasonal Performance Factor refers to heating.


Trane Heat Pump Pros

As Trane heating systems are durable, they will last up to 15 to 20 years if you maintain them properly. In all heat pump models, One of the most reliable Climatuff compressors is used in all Trane heat pump models.

Trane offers eight models of Trane heat pumps at various efficiency levels and prices. So, you can select the model that is suited to your heating and cooling environment.

Most heat pumps have capacities from 1.5 tons/ 18,000 BTU to 5-ton tons/ 60,000 BTU so that you can arrange properly sized to your building.

Trane Earthwise hybrid heat systems come with an ideal combination of a heat pump and a gas furnace for homes in very cold climates.

Trane comfort-R technology works effectively in dehumidifying your home during air conditioning cycles.

All Trane heat pump models are energy-star rated and rebates are offered by many companies across the United States when you install one of the more efficient models of Trane.

Trane's Wifi-connected thermostats can be controlled from the smartphone using the Trane app.

Cons of Trane Heat Pumps

Trane's most efficient heat pump XV20i with 20 SEER/ 10 HSPF is not much efficient than other competitors. Other competitor heat pumps have build with high SEER and HSPF factors.

Trane heat pumps have more costs than Goodman, Amana, Air-Flo and Payne.

Trane warranties on the best models of heat pumps are average. This is somewhat less compared to other brands such as Amana, Goodman, Maytag, Lennox, etc. These brands have longer warranties and include entire product replacement.

Once you have selected the right Trane heat pump depends on your climate, make sure it is sized properly. Don't install the system with too much or too little capacity as it creates many problems. So, you should decide the size before purchasing. However, hope this Traneheat pump reviews guide helped you understand your options.


Trane Furnace Troubleshooting

Trane Furnace Troubleshooting

Trane furnace parts is one of the most reliable heating systems in existence. Every most reliable furnace runs into problems from time to time. So, you may get Trane furnace problems also. You can fix some common problems easily yourself. If you are unfamiliar with fixing the basic issues of your furnace, follow our Trane furnace troubleshooting tips and save money as well as time.










Electric Furnace is Blowing Air but Not Heating

Occasional problems like blocked vents and incorrect thermostat settings may interfere with heating efficiency. Follow the below troubleshooting steps that may solve your problem.

First, you should verify the thermostat settings and it is set to "Heat". If your thermostat has a fan button feature, keep it in the "ON" position.

Still, your furnace not producing heat, you need to increase the temperature point. Choose a temperature setting that is higher than the indoor temperature displayed on your thermostat.

Some thermostats have recommended temperature set points that you have to follow. So, refer to your device’s manual to get additional troubleshooting tips.

If your device not regulating temperature properly, you have to reset the thermostat. If your thermostat has a reset button, simply press it for a few seconds and then release it. However, the resetting thermostat varies depends on the model. So, it's better to refer to your owner's manual.

Now, check the vents and remove obstructions if any that could be blocking airflow. Normally, blocked vents can limit the efficiency of your Trane furnace.

When Heat Not Coming from Trane Gas Furnace

If your furnace does not produce heat from vents when it turn on, it's not a difficult problem. Usually, if your gas furnace doesn't blow hot air, it means that there is a problem with your gas. Your device can't heat the air without supplying energy. Hence, you have to check whether the gas is connected and flowing correctly or not. If not, correct it.

n addition, you will need to verify the pilot light may have gone out. It is a small flame that ignites the main furnace flame. You can get the detailed instructions related to relighting the pilot in the manual. Once verify that the main gas supply line might be turned off.

Examine the drain pan.

All times it may not because of the ignitor itself. Sometimes there is standing water in the drain pan of your Trane furnace. Then, your system will not run to prevent the risk of overflowing nothing but the ignitor won't work. Clean the pump. If it doesn't help, you need to replace the pump assembly.

Check the Ignitor Sensor

The ignitor sensor intimates the furnace when it is safe to ignite. When this sensor senses a flame, it tells the device that it is safe to turn on the gas supply. However, sometimes, it can become dirty and unable to sense the flame. Then, it needs to be cleaned.

Additionally, you need to remember the age of ignitor. Normally, ignitor in the furnace will not work as long as the furnace. Over time, the ignitor will start to lose functionality. You have to change the ignitor if needed.

Final Words

Most of the time, modern Trane furnaces are reliable and have less problems. However, you can fix some basic and common Trane furnace problems easily. Hopefully, these Trane furnace troubleshooting tips will help you to determine the issue and it's solution without much work. If the above tips have not helped to find the source of your problem, then contact an experienced technician.


Sunday, October 10, 2021

How To Fix Noisy Dishwasher

                                                        How to fix noisy dishwasher

A foreign object may be stuck inside the pump or chopper blade area. 

It could happen while cleaning. When a piece of the dish is broken, it will fell straight into the bottom of the unit. Then, it lodged around the machine drain impeller.

If you are getting odd grinding or vibrating sounds during a cycle, then open the door and allow the steam to dissipate. After that pull out the bottom rack and check for any dish parts, glass, or food items in the chopper blade area or pump of your dishwasher.

While reaching the bottom compartment of the dishwasher, you need to remove the internal parts. In that time, you should check for debris on particular components. Make sure they would be cleaned if there is grease or debris build-up.













Insufficient water sprays into the dishwasher.
If there is no sufficient water sprayed into the machine, you can hear a weird grinding noise. So, you will need to verify the inlet valve clogs or any other issues which are preventing water from flowing into the machine.

Dishwasher Making Droning Noise
If your dishwasher makes continuous drone like sounds or the dishwasher makes high pitched noise, then check for the bearings on the circulation pump. When circulation pump bearings are damaged, you can notice these types of sounds.  

Dishwasher circulation pump noise - The water pressure will not be generated through the spray arms when this pump motor bearings are faulty. Replacing the circulation pump bearings is the best way to fix the dishwasher high pitched noise. It also stops the continuous droning,

Dishwasher Making Buzzing Noise
Is your dishwasher making loud buzzing noise? It could happen when dirty water is pushing down the drain. Moreover, this noise is common during the wash cycle as the soft food disposal unit grinding down food particles.
If the buzzing noise is turning into a banging sound, check for the possible causes below.

Spray arms might be hitting the dishes. 
When the spray arms rotate in a circle, you can notice a rhythmic banging. You can fix this by re-adjusting the dish places in the machine. If the banging inside the unit is non-rhythmic, you have to call a plumber to fix the issue.
Most likely, you are experiencing a water pipeline hammer knock sound. It may happen because of sudden valve shutting leads to rapid bursts of water to rattle pipes such that they will bang against the surrounding.

Dishwasher Making Rattling Noise
Rattling sounds are normal when your machine is running. When there are loose forks or dishes that touch each other in the dishwasher, you will get a rattling noise.
Moreover, rattling is normal if there is no water in the dishwasher or if you have used the unit for a long time. Try adding some water to the machine tub to fix the issue.
If rattling becomes too loud, then the cause could be a faulty wash motor.
Run an empty wash cycle in the unit to examine the motor. If rattling noise occurs, the cause could be the faulty motor. Other causes include blocked filter, clogged drain, etc. You have to check and fix the respective issues.

Final Words
If you are not able to fix your dishwasher noise due to technical failures, then contact a professional. We hope that our post on how to fix noisy dishwasher helped to quickly resolve the issues. For further more assistance, you can check your dishwasher manual. If you want to buy any Dishwasher Parts, find them at PartsIPS from various manufactures

Friday, October 8, 2021

How To Clean Manitowoc Ice Machine

 How To Clean Manitowoc Ice Machine

On a customary timetable, a Manitowoc ice machine ought to be cleaned once like clockwork of 6 months. Notwithstanding, there might be times inside that range that require a cleaning of the ice machine. Moreover, you should clean the machine quickly in the event that it has not been on a normal half year upkeep cleaning plan. Likewise, clean the outside of the machine and the encompassing floor region as often as fundamental.








Ice Machine Cleaning

To clean the ice machine, start by eliminating the screws toward the edges of the ice machine's top cover, utilizing a screwdriver. Eliminate the cover. Lift and eliminate the machine's front entryway or, contingent upon the model, essentially open the front entryway. Sit tight for the finish of a gather cycle, when the ice tumbles down from the evaporator, and flip the machine's flip change from ICE to the OFF position.

Manitowoc Ice Machine's Bin Cleaning 

The delivering ice needs to stores into either an ice receptacle or ice gadget until it is prepared for use. Since your ice supply will invest a large portion of your energy in there so keep it clean. Nonetheless, every day cleanings are must to keep away from any wellbeing code infringement. 

Shape and ooze are the most widely recognized impurities that you will find in your ice canister or allocator. By and large, these two impurities for the most part exist in dim and clammy spots. Clean ice is something essential to consider, then, at that point, you will not serve polluted ice to the clients. 

You can utilize an antimicrobial specialist to forestall the development of shape and ooze. Most Manitowoc ice receptacles are comprised of vinyl and plastic with the goal that it is not difficult to eliminate any foreign substances. Bigger ice canisters are made with a hardened steel polyurethane inside, which is likewise easy to clean. The most ideal way of cleaning the ice receptacle is to utilize an EPA-enrolled more clean.

Manitowoc Ice Machine’s Evaporator Cleaning

1.Open the front panel of the ice maker.
2.Ensure all ice is out of the ice bin.
3.Now, tap the "Clean" button on the touchpad. It looks like a hand holding a washrag.
4.Press "turn off when complete" when prompted.
5.The touchscreen will count down as the water trough refills for about a minute.
6.When indicated by the touchscreen, you have to add cleaner to the ice machine. Pour the cleaner 7.between the water curtain and the evaporator. Check the instructions for cleaning your Manitowoc ice 8.machine for the right amount of cleaner to add.
9.Now, click the "chemicals added" button on the touchpad when the above is done.
10.Let the clean cycle run for 24 minutes or until you get confirmation by the touchscreen.

Final Words
Manitowoc ice machine cleaning frequently helps to keep your ice supply sanitary. You should use factory-approved ice machine cleaner and sanitizer. For further more queries, you can refer to the owner's manual. Otherwise, contact the manufacturer's support team. If you need to buy any Manitowoc replacement parts, choose PartsFPS and order online.

Trane Furnace Troubleshooting

Trane Furnace Troubleshooting

Trane furnace is one of the most reliable heating systems in existence. Every most reliable furnace runs into problems from time to time. So, you may get Trane furnace problems also. You can fix some common problems easily yourself. If you are unfamiliar with fixing the basic issues of your furnace, follow our Trane furnace troubleshooting tips and save money as well as time.









Trane Furnace Troubleshooting Guide

Is your Trane furnace not turning on or not blowing hot air? Do you have Trane furnace ignitor problems? Find the solutions below.

Furnace Won’t Turn ON

Is your Trane furnace fail to turn on when you adjust the temperature? It is easy to detect the problem correctly. If your device is completely not turning on, then there could be an issue with the circuit breaker or with the thermostat.

Your furnace's circuit should be turned on. If the circuit is off, just restore the power. Also, check the response of the thermostat. If none of the before didn't help you, simply call a technician.

Electric Furnace is Blowing Air but Not Heating

Occasional problems like blocked vents and incorrect thermostat settings may interfere with heating efficiency. Follow the below troubleshooting steps that may solve your problem.

First, you should verify the thermostat settings and it is set to "Heat". If your thermostat has a fan button feature, keep it in the "ON" position.

Still, your furnace not producing heat, you need to increase the temperature point. Choose a temperature setting that is higher than the indoor temperature displayed on your thermostat.

Some thermostats have recommended temperature set points that you have to follow. So, refer to your device’s manual to get additional troubleshooting tips.

Check for the clogged air filter.

To prevent the ignitor type of problems, you should change the air filter regularly. When the air filter is clogged, the furnace will no longer ignite. So, it's the best way to check the air filter when your ignitor not working.  

Inspect the Gas Supply

When there is a problem with your gas supply, it causes your furnace ignitor to fail to ignite. If no problem is found with your home's gas supply, then consider that there could be an issue with the gas supply to your Trane furnace. Contact an expert to fix the issue.

Check the Ignitor Sensor

The ignitor sensor intimates the furnace when it is safe to ignite. When this sensor senses a flame, it tells the device that it is safe to turn on the gas supply. However, sometimes, it can become dirty and unable to sense the flame. Then, it needs to be cleaned.

Additionally, you need to remember the age of ignitor. Normally, ignitor in the furnace will not work as long as the furnace. Over time, the ignitor will start to lose functionality. You have to change the ignitor if needed.

Final Words

Most of the time, modern Trane furnaces are reliable and have less problems. However, you can fix some basic and common Trane furnace problems easily. Hopefully, these Trane furnace troubleshooting tips will help you to determine the issue and it's solution without much work. If the above tips have not helped to find the source of your problem, then contact an experienced technician.